Skip to main content
INDUS
Precision Motion & Automation
Standards & Quality

Quality, Standards & Engineering References

What Standards Mean for Your Application — and What They Do Not

Standards and certifications are specific in scope. A product may reference a standard during design without being independently certified to it. A company certification covers defined processes, not the entire product catalogue. This page clearly separates confirmed certifications, design references, applicable standards, and testing procedures.

Engineering Enquiry
Important: Standards compliance, certification, calibration, verification, and testing are distinct concepts. INDUS publishes this page to help customers understand which standards are relevant to their application. Claims on this page are scoped to the referenced standard and product. Do not infer that the entire catalogue is certified because one product references a standard.

Design References

Engineering Design Standards & References

INDUS engineering work uses the following international standards as design references and calculation bases. "Referenced" means the standard is used as an engineering methodology. "Independently certified" means an external certification body has issued a certificate.

StandardScopeHow INDUS Uses ItStatus
ISO 9283:1998Manipulating industrial robots — performance criteria and testingKinematic accuracy, repeatability, and path accuracy specification methodologyDesign reference
ISO 13849-1:2023Safety of machinery — safety-related parts of control systemsSISTEMA calculations for safety function PLd/PLe determinationEngineering calculation
IEC 62061:2021Functional safety of safety-related control systemsSILCL determination for safety-integrated drive functionsEngineering reference
ISO 10218-1:2011Robots for industrial environments — safety requirements for robotsRobot system design requirementsDesign reference
ISO 10218-2:2011Robots for industrial environments — safety for integrationRobot cell integration safety requirementsApplied during integration projects
ISO 12100:2010Safety of machinery — risk assessmentHazard identification and risk reduction methodologyApplied during engineering assessment
ISO/TS 15066:2016Collaborative robots — safety requirementsPower and force limiting operation parametersApplied to cobot application design
DIN 3990Calculation of load capacity of cylindrical gearsGear tooth strength and safety factor calculationsCalculation reference
IEC 61000-4 seriesElectromagnetic compatibility — immunityEMC immunity requirements for electrical productsProcurement specification reference
ISO 3408Ball screws — acceptance conditions and testsBall screw accuracy grade specificationDesign and procurement reference

Certification Scope

Product Certification Scope

Selected products in the INDUS catalogue carry certifications from their manufacturers. Certification scope is specific to the product model and configuration tested. INDUS re-sells and integrates these products — the manufacturer's certificate applies to the product as manufactured, not to the complete system as integrated.

CE Marking

Products supplied by INDUS for the European market carry CE marking where applicable. CE marking is based on the manufacturer's Declaration of Conformity. Scope and applicable directives (Machinery Directive, Low Voltage Directive, EMC Directive) vary per product. Customers should request the Declaration of Conformity for the specific product.

Safety Integrity Level (SIL)

Functional safety components (servo drives with STO, safety PLCs, light curtains, scanners) may carry SIL ratings from IEC 61508 or IEC 62061. SIL ratings apply to the component in isolation. System-level SIL determination requires a full safety function analysis across all components in the safety chain.

UL / CSA Listing

Selected products may carry UL or CSA listings for North American markets. Availability depends on the product family and model. Specify the required standard when placing an enquiry.

Company Certification: INDUS is an engineering and distribution company. Quality commitments are project-specific and defined in project documentation. If your procurement requires a specific company certification, raise this during the enquiry stage.

Verification & Acceptance

Engineering Testing & Project Acceptance

For engineering service engagements, INDUS defines and executes acceptance testing as part of the project scope. Testing is evidence-based and documented.

Factory Acceptance Test (FAT)

Individual subsystem verification before delivery. Covers axis homing, communication continuity, safety function activation, and motion profile validation. FAT protocol is agreed during project scoping.

Site Acceptance Test (SAT)

Full system verification at the customer site after installation. Covers coordinated motion, I/O integration, production cycle execution, and alarm handling. SAT sign-off is required before handover.

Safety Verification

SISTEMA calculations for safety function Performance Level. Safety circuit continuity testing per ISO 13849. Documented for each safety function in the system.

Servo Loop Tuning & Validation

Frequency response measurement, following error verification, and cycle time confirmation. Results documented in commissioning report.

Application-Specific Requirements

What Requires Application-Specific Assessment

Not all standards apply to every application. The following items require project-specific determination — they cannot be confirmed without knowing the exact hardware, application, and operating environment.

System-level Performance Level (PL) for functional safety — requires full safety function analysis including all components

ATEX / IECEx zone classification compliance — requires hazardous area classification data

Food-contact and hygienic design compliance — requires material and surface finish confirmation for the specific product

Cleanroom classification (ISO 14644) — requires contamination testing of the specific configuration

Pressure vessel, pressure equipment, or PSSR compliance — not applicable to standard motion systems

Medical device regulatory requirements (MDR, FDA) — out of scope for standard robotics components

EMC system-level compliance — requires testing of the complete installed system