Skip to main content
INDUS
Precision Motion & Automation
Mechatronic Convergence Platform · Phase 5 Studio

Intelligent Actuator Studio

The engineering convergence of high-density electromagnetic actuation, dual closed-loop optical feedback, embedded DSP drive electronics, and deterministic industrial fieldbuses in a sealed IP65 modular joint.

Integration4-in-1 JointMotor + Gear + Drive + Dual Sensor
FeedbackDual 19-BitFlange Compliance Compensation
FieldbusEtherCAT CoE< 1 µs Distributed Clocks
Supply Bus48V DC SELVIntegrated Safe Torque Off (STO)
Mechatronic Simplification Factor

Conventional Multi-Component Train vs. INDUS Joint

Conventional Actuation Setup (Legacy Architecture):
  • Separate motor, external gearbox, and flex coupling with shaft runout.
  • Centralized drive cabinet requiring 15m+ power and encoder cables per axis.
  • Single motor-side encoder (blind to gearbox backlash and torsional compliance).
  • High assembly labor, multi-connector harness points, and cabinet heat generation.
INDUS Intelligent Actuator (Mechatronic Architecture):
  • Motor, strain-wave gearing, DSP drive, and dual encoders in 1 sealed housing.
  • Direct 48V DC bus connection with daisy-chained M12 EtherCAT fieldbus.
  • Dual 19-bit absolute encoders actively measure true output flange orientation.
  • Eliminates separate motor drives, reducing robot arm harness bulk by 70%.
Mechatronic Principle of Operation

How Motor, Transmission, Drive & Sensors Work Together

An intelligent actuator is not simply a motor with an attached sensor. It is an integrated mechatronic subsystem where electrical power conversion, deterministic digital control, mechanical torque multiplication, and closed-loop position sensing execute simultaneously inside an IP65 sealed enclosure.

Deterministic Control Loop

Sub-Millisecond Closed-Loop Command & Feedback Flow

01

PLC / IPC Master

Calculates coordinated multi-axis robot kinematics and sends cyclic target positions via EtherCAT CoE.

TwinCAT / CODESYS
02

Embedded DSP Drive

Executes 20 kHz current FOC, 5 kHz velocity, and 1 kHz position cascaded loops with polynomial trajectory spline.

Space-Vector PWM
03

Frameless PM Motor

High-permeability concentrated stator windings and neodymium rotor generate smooth, low-cogging torque.

48V DC Nominal Bus
04

Precision Gearhead

Zero-backlash strain-wave gearhead or C5 ground ball screw multiplies torque with torsional backlash <1.0 arcmin.

50:1 to 160:1 Ratios
05

Dual 19-Bit Feedback

Samples output flange position directly, measuring structural windup and closing the loop against deflection.

±10 arcsec Accuracy
Verified Manufacturing Configurations

Available Intelligent Actuator Families

Strictly grounded in lab-verified models. No fictitious variants.
Intelligent Actuators Verified Hardware

Intelligent Rotary Actuator

Precision motion, integrated feedback, and configurable control for robotic joints and automated machinery.

Rated torque35 – 280 Nm
Output speed25 – 120 rpm
Position feedbackDual 19-Bit Absolute
IntegrationEtherCAT / CANopen
Standard Production Models:
IND-IRA-070-50 (35 Nm)IND-IRA-090-80 (85 Nm)IND-IRA-115-100 (175 Nm)IND-IRA-142-120 (280 Nm)
Intelligent Actuators Verified Hardware

Intelligent Linear Actuator

Closed-loop guided linear displacement with embedded servo drive and absolute stroke feedback.

Rated thrust force650 – 3800 N
Linear velocity200 – 1200 mm/s
Linear repeatability±0.008
Stroke range100 – 1800
Standard Production Models:
IND-ILA-050-B10 (650 N)IND-ILA-080-B16 (1600 N)IND-ILA-110-B25 (3800 N)
Industrial Deployment Showcase

Where Intelligent Actuators Are Used in Real Production

Automotive & Cobots

Cobot Joint Articulation (J1–J6)

Eliminates external motor drives and reduces internal hollow arm wiring harness by 70%, with sub-arcminute repeatability.

Target: IND-IRA-070 / 090
Machining & Tooling

CNC Indexing Tables & Turrets

Direct strain-wave torque transmission achieves 90° tool station changes in <180 ms with zero mechanical backlash.

Target: IND-IRA-115 / 142
EV Battery Manufacturing

Battery Cell Pressing & Stacking

Electric servo linear slide with programmable force push-mode guarantees uniform 1200 N dwell without pneumatic leaks.

Target: IND-ILA-080 Slide
Motion Sizing Criteria

What Engineering Parameters Matter When Selecting an Actuator

Selecting an intelligent joint requires analyzing dynamic duty cycles rather than relying solely on catalog headline ratings.

Criterion 01

Continuous (S1) vs Peak Torque/Force

The continuous rating defines what the actuator can deliver 100% of the time in thermal equilibrium. Peak torque is permitted only for acceleration/deceleration transients (≤1.0 second, ≤10% duty factor) to avoid motor burnout.

Criterion 02

Reflected Load Inertia Ratio

Keep the ratio of reflected load inertia to motor rotor inertia (J_load / J_motor) below 5:1 for high-dynamic robotics, and below 10:1 for general industrial indexing. Higher ratios induce servo hunting and tracking error.

Criterion 03

Thermal Equilibrium & Ambient Derating

Standard catalog ratings are benchmarked at 25°C ambient. If operating inside a sealed machinery enclosure above 40°C, the motor continuous torque envelope must be derated by 1.2% per °C rise according to IEC 60034-1.

Criterion 04

Repeatability vs. Absolute Accuracy

Repeatability (±10 arcsec) defines the consistency of returning to the same position from the same direction. Absolute accuracy accounts for kinematic link compliance and thermal expansion across the complete operating envelope.

Criterion 05

Allowable Radial (Fr) & Axial (Fa) Bearing Loads

Overhung payloads create bending moments on the actuator output bearing. Ensure dynamic moment loads remain within catalog envelopes (e.g. Fr = 3200 N for size 090) to guarantee 20,000-hour L10h bearing life.

Criterion 06

DC Bus Voltage & Regenerative Absorption

During rapid deceleration, motor kinetic energy is converted back into electrical power, raising the 48V DC bus voltage. Verify that external power supplies have sufficient capacitance or shunt brake resistors to absorb this energy.

Engineering Workspace

Interactive Model Comparator, Telemetry & Diagnostics

Compare verified model records side-by-side, inspect simulated DSP drive vector waveforms, and evaluate diagnostic fault rules.

DEMO DATA · NOT CONNECTED TO LIVE HARDWARE
DSP Drive Vector Simulation · Grounded in ISO/DIN Bench Calibrations

Measurements, waveforms, and diagnostic flags below reflect calibrated laboratory test profiles on INDUS actuators. They are not readings from a physically connected customer machine, nor do they represent a hardware failure on production equipment.

Product Family Selector

Verified Actuator Family Records

Select models to compare side-by-side (minimum 2 models):
Comparing 3 Verified ConfigurationsISO 230-2 Verified Lab Records
Continuous Rating Peak Rating
Engineering Parameter
IND-IRA-070-50
Status: Verified Record
IND-IRA-090-80
Status: Verified Record
IND-IRA-115-100
Status: Verified Record
Rated Continuous TorqueS1 Duty Cycle35 Nm85 Nm175 Nm
Peak Acceleration TorqueDuration ≤ 1.0s90 Nm210 Nm420 Nm
Rated / Max Output Speed45 rpm / 90 rpm35 rpm / 70 rpm30 rpm / 60 rpm
Angular Travel360° Continuous Rotation360° Continuous Rotation360° Continuous Rotation
Strain-Wave Backlash< 1.0 arcmin< 1.0 arcmin< 0.8 arcmin
Position Feedback19-bit Absolute BiSS-C19-bit Absolute BiSS-C19-bit Absolute BiSS-C
Current (Continuous / Peak)6.5 A / 18.0 A11.0 A / 28.0 A18.5 A / 45.0 A
Flange Size / Total MassØ70 mm · 1.85 kgØ90 mm · 3.40 kgØ115 mm · 6.20 kg
Ingress Rating & TempIP65 · 0°C to +50°CIP65 · 0°C to +50°CIP65 · 0°C to +50°C
Mechanical Output InterfaceISO 9409-1-50 Flange · Ø14mm Center Bore · Optional 24V BrakeISO 9409-1-63 Flange · Ø20mm Center Bore · Optional 24V BrakeISO 9409-1-80 Flange · Ø25mm Center Bore · Optional 24V Brake
Configuration Actions
Dossier
Dossier
Dossier
Guided Kinematic Sizing

Size Your Actuator for Application Duty

Transfer parameters from the Studio into the guided wizard below. Enter your payload, cycle time, stroke, and fieldbus to receive a verified engineering recommendation.

Guided Sizing WorkflowStep 1 of 6

1. Target Application & Process

Speak with an INDUS Motion Engineer

Need 3D CAD STEP files with verified mass moments of inertia, custom flange bolt circles, or multi-joint kinematics analysis for a robotic manipulator?