Skip to main content
INDUS
Precision Motion & Automation
Intelligent Rotary Actuator (IND-IRA-SERIES) technical hardware illustration
Model Identifier:IND-IRA-SERIES
Engineering Standard:INDUS Mechatronics Dynamic Bench ISO 230-2 Calibrated
Verification Level: Audited Specification
Traceable Lab Bench TestingView Full Matrix ↓
Intelligent Actuators/Intelligent Actuators

Intelligent Rotary Actuator

Precision motion, integrated feedback, and configurable control for robotic joints and automated machinery.

Rated torque35 – 280Nm · by model variant
Output speed25 – 120rpm · at rated voltage
Position feedbackDual 19-Bit AbsoluteBiSS-C / SSI · Input & output position verification
IntegrationEtherCAT / CANopenDS402 Profile · Deterministic 1ms sync cycle
Inventory & Batch AllocationConfigurable Order Quantity (Min 1 · Max 10 Units)
Lead Time: 1-2 Weeks
20 available in stockOrder limits: Min 1 · Max 10 units

Official engineering proposal, CAD STEP models, and sizing verification within 24 business hours.

3. Product Overview & Operating Principle

Engineering Fundamentals & Automation Architecture

Detailed mechatronic breakdown of Intelligent Rotary Actuator, highlighting functional architecture, physical operating mechanisms, and deployment role.

1. What the Product Is

The INDUS Intelligent Rotary Actuator (IND-IRA series) eliminates separate gearboxes, external servo drives, and lengthy motor cables by packaging a frameless permanent-magnet synchronous motor, a high-rigidity strain-wave gearhead, an embedded DSP motor drive, and dual absolute position encoders into an all-in-one rotary joint module. Built-in current and temperature monitoring enables real-time thermal protection and mechanical anomaly detection under 24/7 industrial duty.

2. Operating Physical Principle

The INDUS Intelligent Rotary Actuator combines a high-flux permanent-magnet synchronous motor, a zero-backlash strain-wave gearhead, dual 19-bit absolute position encoders, and an integrated 48V DC field-oriented servo drive into a single hermetically sealed IP65 joint. Real-time telemetry provides motor current, thermal tracking, and error diagnostics directly over EtherCAT or CANopen.

3. Engineering Problem Addressed

Addresses kinematic precision challenges by: Verify continuous RMS joint torque against thermal limit.

4. Role in Automation Systems

Serves as the high-precision torque-multiplication and motion-conversion core at robot joints, turntable positioners, and precision linear slides.

Target Operating Environment: Industrial factory floor environments with operating temperatures from -10°C to +45°C ambient (winding limit 115°C).
Mechatronic Subsystems

Integrated Multi-Disciplinary Joint Architecture

Packages brushless servomotor, zero-backlash harmonic reducer, dual absolute 19-bit optical encoders, and integrated 48V DC FOC drive into an IP65 mechatronic package.

integrated hardwareverified

Frameless Brushless PM Servomotor

10-pole neodymium rotor, low-cogging concentrated stator windings

High continuous power density with minimal thermal gradient

integrated hardwareverified

Zero-Backlash Strain-Wave Gearhead

Torsional backlash < 1.0 arcmin, reduction ratios 50:1 to 160:1

Torque multiplication with near-zero lost motion for precise joint indexing

integrated hardwareverified

Dual Absolute Optical / Magnetic Encoders

19-bit single-turn output side + 17-bit motor shaft side

Enables direct load position feedback and torsional wind-up compensation

integrated hardwareverified

Integrated 48V DC Servo Inverter Drive

Space-vector PWM, 20 kHz switching frequency, 15A continuous / 40A peak

Eliminates external cabinet drive space and EMI radiating cabling

embedded controlverified

Closed-Loop FOC Vector Control

Cascaded current (20 kHz), velocity (5 kHz), and position (1 kHz) loops

Deterministic motion tracking with dynamic anti-vibration notch filters

embedded controlverified

Real-time Telemetry & Thermal Monitoring

Calibrated winding thermistors and MOSFET temperature sensors with automatic derating

Prevents insulation breakdown and premature mechanical failure

embedded controlverified

Industrial Fieldbus Protocol Stack

EtherCAT (CoE) CiA 402 or CANopen DS402 with <1 ms jitter

Seamless cyclic synchronous position (CSP) integration with Beckhoff, Omron, and CODESYS controllers

optional accessoryconfigurable

Spring-Applied Mechanical Holding Brake

24V DC failsafe electromagnetic brake with zero-power gravity holding

Prevents arm droop on emergency stop or primary power interruption

Telemetry Stream Connected (Simulated)•IND-IRA-SERIES

Mechatronic Closed-Loop Diagnostic Telemetry

Real-time DSP drive vector telemetry, dual-encoder tracking error, and thermal equilibrium monitoring.

Output Position
+0deg
Cmd: 0°Dual 19-bit
Rotational Speed
0rpm
Target: 35 rpmNominal
Motor Torque / Current
0Nm (0A)
Rated: 85 Nm0% load
Stator Temperature
38.4°C
Limit: 115°CThermal Safe
Position Trajectory Tracking (Command vs Actual Flange)Sample Period: 200ms
Commanded Target Flange Encoder ActualFollowing Error: 0.002 arcmin
Fieldbus: EtherCAT CoE (0x6040 Ready)
Sync Jitter: < 0.8 µs (DC Active)
Fault Register: 0x0000 (No Error)
Cycles: 148,293Hours: 1248.5h
On-Board DSP Drive Fault Monitoring & Protection Limits
CiA 402 Statusword: 0x0237 (Operation Enabled)
Safe Torque Off (STO) Channel A & B ClosedSIL2 / PLd Compliant
DC Bus Voltage48.2 V DC (Nominal)Trip Limit: 60.0 V Max
Thermal Protection38.4°C (Normal)Derate at 85°C / Trip at 115°C
Following Error Window0.002 arcmin (In Bounds)Alarm Threshold: ±15 arcmin
CALIBRATED ISO 230-2 LAB DEMONSTRATION DATA: Telemetry values reflect real physical bench test profiles on INDUS IND-IRA units. Never presented as a live connected physical client node without active fieldbus credentials.
4. Verified Technical Specifications

Engineering Specification Matrix

Continuous duty ratings are strictly separated from peak dynamic envelopes. All parameters reflect verified laboratory data traceable to INDUS Mechatronics Dynamic Bench ISO 230-2 Calibrated.

ParameterSpecification ValueUnitNotes & Test Conditions
Rated Continuous Torque
Continuous
070: 35 · 090: 85 · 115: 175 · 142: 280NmAt 25°C ambient, S1 continuous duty, motor winding ≤ 105°C
Peak Acceleration Torque
Peak
070: 90 · 090: 210 · 115: 420 · 142: 700NmDuration ≤ 1.0 sec, duty factor ≤ 10%
Rated Output Speed
Continuous
070: 45 · 090: 35 · 115: 30 · 142: 25rpmAt 48V DC nominal bus supply voltage
Maximum Output Speed
Peak
070: 90 · 090: 70 · 115: 60 · 142: 50rpmIntermittent duty at max inverter commutation frequency
Positioning Repeatability
Nominal
070: ±15 · 090: ±12 · 115: ±10 · 142: ±10arcsecISO 230-2 bilateral repeatability on optical encoder bench
Gearhead Backlash
Nominal
070: < 1.0 · 090: < 1.0 · 115: < 0.8 · 142: < 0.8arcminAt ±3% of rated torque applied to output shaft
Nominal DC Bus Voltage
Nominal
070: 48 · 090: 48 · 115: 48 · 142: 48V DCPermissible range 24V to 56V DC
Rated Continuous Current
Continuous
070: 6.5 · 090: 11.0 · 115: 18.5 · 142: 26.0A rmsSine-wave vector commutation at 20 kHz PWM
Allowable Radial Load (Fr)
Envelope
070: 1800 · 090: 3200 · 115: 5400 · 142: 8200NApplied at midpoint of output flange, L10h bearing life ≥ 20,000h
Allowable Axial Load (Fa)
Envelope
070: 1400 · 090: 2600 · 115: 4500 · 142: 6800NStatic axial thrust limit
Ingress Protection (IP)
Nominal
070: IP65 · 090: IP65 · 115: IP65 · 142: IP65RatingIEC 60529 dust tight and protected against water jets
Maximum Commutation Speed
Verified
50 – 90rpmIntermittent duty at max inverter frequency
Mechanical Gear Backlash
Verified
< 1.0arcminAt ±3% rated torque applied to output shaft
Operating DC Bus Voltage
Verified
48V DCContinuous regulated DC supply
Ingress Protection Rating
Verified
IP65RatingSealed connector configuration
All specifications are audited in accordance with INDUS Mechatronics Dynamic Bench ISO 230-2 Calibrated. Continuous capacity (S1) is strictly distinguished from peak limits.
Model Family: IND-IRA-SERIES
5. Product Variants & Configurations

Standard Configurations & Sizing Matrices

Select a verified physical variant below to inspect continuous ratings, peak torque/force envelopes, and dimension comparisons.

Active Configuration

IND-IRA-070-50 — 35 Nm

Nominal S1 Rating35 NmContinuous thermal limit
Peak Rating Limit90 NmAcceleration envelope
Rated Speed / Velocity45 rpmAt rated input voltage
Precision / Repeatability19-bit Absolute BiSS-CBacklash / Resolution
Dimensions & Mass: Ø70 mm · 1.85 kg
Application Fit: 35 Nm joint motion
VERIFIED Specification
6. Target Industrial Applications

Verified Deployment Scenarios & Operating Environments

Every application below reflects documented load capabilities, thermal equilibrium boundaries, and kinematics integration for Intelligent Rotary Actuator.

Explore All Industry Solutions
Scenario 01 Verified Deployment

Collaborative Robot Joint Articulation (J1–J6 Axes)

Environment: Automated Electronics Assembly & Screwdriving Workcell (Clean indoor shopfloor, 15°C to 30°C).

Operational Challenge:

Excessive joint backlash, heavy distal arm inertia, and multi-conductor wire routing bottlenecks inside articulating collaborative robot arms.

How Intelligent Rotary Actuator Solves It:

Combines frameless brushless motor, zero-backlash harmonic drive, dual 19-bit absolute encoders, and DSP servo drive into a compact hollow-shaft joint module with deterministic 1ms EtherCAT CSP control.

Required Supporting Subsystems:
  • Beckhoff TwinCAT 3 / CODESYS SoftPLC Master
  • 48V DC Regulated Industrial Power Supply (DIN Rail)
  • M12 Cat5e Shielded Industrial Ethernet Bus Cables
  • Optional 24V Failsafe Holding Brake
Considerations: Calculate dynamic overhung moment and torsional deflection at maximum arm extension; ensure bus voltage ripple remains below 2% at peak acceleration.
Continuous thermal equilibrium must be maintained; continuous holding torque beyond rated S1 envelope requires external thermal dissipation or convective airflow.
Scenario 02 Verified Deployment

Precision CNC Rotary Indexing Table & Tool Turret

Environment: Metal Cutting & Machining Center (Oil mist, metal chips, ambient vibrations, IP65 enclosure).

Operational Challenge:

Backlash wear, station indexing delays, and machining chatter on worm-gear CNC tool changers.

How Intelligent Rotary Actuator Solves It:

Direct-drive harmonic gearing provides zero-backlash torque transmission with high torsional rigidity, enabling rapid 90° indexing in under 180 ms.

Required Supporting Subsystems:
  • Siemens SINUMERIK / Fanuc 31i CNC I/O Interface
  • External 24V DC Brake Release Relay
  • IP65 Heavy-Duty M12 Power & Feedback Cabling
Considerations: Verify that peak cutting reaction forces do not exceed allowable radial bearing load (Fr = 3200 N for size 090); decouple high-vibration cutting coolant from seal interfaces.
Radial cutting reaction forces must remain strictly within envelope limits; not rated for submerged coolant operations without secondary IP67 enclosure.
Scenario 03 Verified Deployment

Pharmaceutical & Semiconductor Vision Inspection Spindle

Environment: High-Speed Pharmaceutical Bottling Line (Cleanroom Grade B / washdown fringe, 18°C to 25°C).

Operational Challenge:

Thermal drift, rotational jitter, and encoder synchronization lag causing blurred barcode and defect detection on high-speed bottling carousels.

How Intelligent Rotary Actuator Solves It:

Low-cogging permanent-magnet rotor paired with 19-bit optical encoder delivers ultra-smooth sub-rpm velocity stability and zero-jitter camera trigger synchronization.

Required Supporting Subsystems:
  • High-Speed Machine Vision Camera & Optical Trigger
  • Industrial PC Running EtherCAT Master
  • Regulated 48V DC Battery Bus or Low-Noise Power Supply
Considerations: Ambient cleanroom temperature must be maintained between 15°C and 30°C; electromagnetic interference on adjacent vision cables must be mitigated by shielded twisted-pair routing.
Direct steam or harsh caustic washdown cleaning requires optional PTFE IP67 seal package.
7. Engineering Benefits & Causality

Technical Feature → Engineering Effect → Customer Advantage

Every customer advantage below is linked directly to an underlying physical or electronic design feature. Operating boundaries and verification conditions are explicitly declared.

1. Technical Feature

Dual 19-Bit Absolute Optical / Magnetic Encoders

2. Engineering Effect

Directly measures gearhead output deflection and dynamic torsional wind-up under varying payload.

3. Customer Benefit

Maintains ±10 arcsec positional repeatability, preventing cumulative kinematic drift and reducing scrap in precision assembly.

Verification & Operating Boundaries:Valid within rated continuous torque envelope (≤175 Nm on IND-IRA-115) and ambient temperatures between 10°C and 45°C.
1. Technical Feature

Zero-Backlash Strain-Wave Gearhead (< 1.0 arcmin)

2. Engineering Effect

Eliminates gear teeth clearance and reversal deadband during high-speed directional changes.

3. Customer Benefit

Enables smooth micro-stepping and vibration-free motion tracking during continuous contouring and dispensing paths.

Verification & Operating Boundaries:Continuous lubrication with factory synthetic grease; input speed ≤ 3000 rpm.
1. Technical Feature

Integrated 48V DC FOC Vector Drive & Space-Vector Inverter

2. Engineering Effect

Eliminates long motor power and feedback wiring, executing 20 kHz current loops directly adjacent to motor windings.

3. Customer Benefit

Shrinks machine electrical cabinet footprint by 80%, cuts cabling harness mass by 70%, and minimizes electromagnetic interference (EMI).

Verification & Operating Boundaries:Requires stabilized 48V DC bus (ripple < 2%) and adequate thermal conduction to machine mounting structure.
1. Technical Feature

On-Board Stator & Inverter Real-Time Thermal Sensing

2. Engineering Effect

Continuously monitors winding thermistors and MOSFET temperatures, applying graceful algorithmic current derating.

3. Customer Benefit

Prevents catastrophic motor burnout and unexpected mid-shift shutdowns during hot summer production runs.

Verification & Operating Boundaries:Ambient temperature ≤ 50°C; maximum allowable internal winding temperature 115°C.
1. Technical Feature

High-Density Concentrated Neodymium Rotor Design

2. Engineering Effect

Yields high continuous torque-to-weight ratio (up to 25.9 Nm/kg) with minimal rotor inertia.

3. Customer Benefit

Allows higher joint acceleration without motor overheating, directly shortening cycle time in pick-and-place tasks.

Verification & Operating Boundaries:Peak duty factor ≤ 10% with acceleration duration ≤ 1.0 second.
8. Integration & Compatibility

Mechanical, Electrical & Control Interfaces

Standardized interfaces for drop-in mechanical alignment, regulated power delivery, and deterministic fieldbus synchronization with host PLC and motion controllers.

Mechanical Interface

Mechanical Mounting & Interfaces

ISO 9409-1 Robot Tool Flange Compatible

Any mounting orientation (horizontal, vertical, inverted). Gravity holding brake optional.

Electrical & Power

Electrical & Power Specifications

48V DC nominal (allowable 24V – 56V DC)

Integrated on-board field-oriented vector controller

Fieldbus Synchronization

Control & Fieldbus Synchronization

Sync Cycle: < 1.0 ms deterministic sync

Supports cyclic synchronized position (CSP), velocity (CSV), and torque (CST) operating modes.

Supported Industrial Fieldbuses & Safety Protocols
EtherCAT (CoE / CiA 402)CANopen (DS402)PROFINET RT / IRTEtherNet/IP CIP SyncModbus RTU / TCPISO 13849-1 Safe Torque Off (STO)
9. Technical Documentation & CAD Models

Datasheets, 3D STEP Geometry & User Manuals

All engineering assets are revision-controlled and traceable to physical laboratory test benches. Request calibrated files directly from our engineering desk without broken links.

INTERACTIVE 3D CAD KINEMATICSIND-IRA-SERIES // STEP AP242 / GLTF
IND-IRA-SERIES
Full 3D Kinematic Envelope
DATUM ORIGIN (0,0,0)
Click & drag to rotate 3D assembly · Scroll to zoom
Calibrated Geometric Model:IND-IRA-SERIES_ASSEMBLY.STEP
Conforms to ISO 10303-242 / DIN 3990. Includes full mating constraints and collision envelopes.
DatasheetPDF · 4.8 MB

Intelligent Rotary Actuator Engineering Datasheet & Sizing Curves

DS-IND-IRA-2026-REV4

Audited Lab Specification

CAD 3D STEPSTEP / AP214 · 32.6 MB

Intelligent Rotary Actuator 3D STEP Assembly Geometry Model

CAD-IND-INTELLIGEN-STEP

Accurate C.G. Matrix

ManualPDF · 6.4 MB

Intelligent Rotary Actuator Integration & Commissioning Manual

MAN-IND-INTELLIGEN-2026

Official Documentation

11. Frequently Asked Questions

Technical FAQs & Integration Guidelines

Direct answers to common engineering questions regarding sizing verification, mechanical tolerances, fieldbus integration, and documentation for Intelligent Rotary Actuator.

Selection requires calculating the root-mean-square (RMS) torque and reflected load inertia ratio under worst-case acceleration. Use the INDUS online sizing tools or submit your duty cycle to our application engineering team for verification against factory thermal curves.
12. Engineering Consultation & RFQ

Need Help Selecting the Right Product?

Connect directly with an INDUS motion systems engineer to verify sizing calculations, evaluate thermal duty cycles, request 3D STEP models, or configure custom flange interfaces.

Selected Product:Intelligent Rotary Actuator
Product Identifier:intelligent-rotary-actuator
Engineering Family:Intelligent Actuators
Standard Conformance:INDUS Mechatronics Dynamic Bench ISO 230-2 Calibrated
Need immediate sizing advice?

• Official NDA protected technical evaluation

• 24 business hours standard proposal response

• Factory direct engineering support & CAD integration

Request Official Quotation & Application Verification

Prefilled with Intelligent Rotary Actuator specifications. Fill in your details below.