Skip to main content
INDUS
Precision Motion & Automation
Dual-Channel Safety Evaluation Relay with Force-Guided Contacts (IND-SAF-FORCE-GUIDED-SAFETY-RELAY) technical hardware illustration
Model Identifier:IND-SAF-FORCE-GUIDED-SAFETY-RELAY
Engineering Standard:ISO 13849-1
Verification Level: Audited Specification
Traceable Lab Bench TestingView Full Matrix ↓
Safety & Intelligent Systems/Safety Controllers & Interlocks

Dual-Channel Safety Evaluation Relay with Force-Guided Contacts

Evaluates emergency stop buttons, interlock switches, and light curtains for small standalone machines without a safety PLC.

Contacts3 Safe NO contacts + 1 Auxiliary NC contactVerified rating
Safety RatingPLe (ISO 13849-1) / SIL 3 (IEC 62061)Verified rating
Mechanical Life> 10 million cyclesVerified rating
Inventory & Batch AllocationConfigurable Order Quantity (Min 1 · Max 10 Units)
Lead Time: 1-2 Weeks
20 available in stockOrder limits: Min 1 · Max 10 units

Official engineering proposal, CAD STEP models, and sizing verification within 24 business hours.

3. Product Overview & Operating Principle

Engineering Fundamentals & Automation Architecture

Detailed mechatronic breakdown of Dual-Channel Safety Evaluation Relay with Force-Guided Contacts, highlighting functional architecture, physical operating mechanisms, and deployment role.

1. What the Product Is

Evaluates emergency stop buttons, interlock switches, and light curtains for small standalone machines without a safety PLC.

2. Operating Physical Principle

Mechanically linked force-guided contacts (EN 50205 Type A); if a normally open contact welds closed, normally closed contacts cannot close.

3. Engineering Problem Addressed

Eliminates operational failure modes related to: Category 4 / PLe compliance, Manual monitored reset or automatic reset selection.

4. Role in Automation Systems

Monitors safety zones, prevents human-machine collisions, and ensures compliance with global industrial safety directives (ISO 13849-1).

Target Operating Environment: Industrial robotics cells, semiconductor cleanrooms, automotive assembly lines, and high-throughput automated packaging machinery.
4. Verified Technical Specifications

Engineering Specification Matrix

Continuous duty ratings are strictly separated from peak dynamic envelopes. All parameters reflect verified laboratory data traceable to ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots).

ParameterSpecification ValueUnitNotes & Test Conditions
Contacts
Verified
3 Safe NO contacts + 1 Auxiliary NC contactNAudited per Relays with Forcibly Guided Contacts Standard EN 50205
Safety Rating
Verified
PLe (ISO 13849-1) / SIL 3 (IEC 62061)—Audited per Relays with Forcibly Guided Contacts Standard EN 50205
Mechanical Life
Verified
> 10 million cycles—Audited per Relays with Forcibly Guided Contacts Standard EN 50205
System Interface Compatibility
Standard
Standard 24V AC/DC safety circuitsStandardSupported physical and electronic mating connections
All specifications are audited in accordance with ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots). Continuous capacity (S1) is strictly distinguished from peak limits.
Model Family: IND-SAF-FORCE-GUIDED-SAFETY-RELAY
5. Product Variants & Configurations

Standard Configurations & Sizing Matrices

Select a verified physical variant below to inspect continuous ratings, peak torque/force envelopes, and dimension comparisons.

Active Configuration

IND-SAF-FORCE-GUIDED-SAFETY-RELAY-STD-01 — Standard Rating

Nominal S1 RatingStandardContinuous thermal limit
Peak Rating LimitPeak Dynamic Limit ≤ 2.0x S1Acceleration envelope
Rated Speed / VelocityRatedAt rated input voltage
Precision / RepeatabilityPrecision ClassBacklash / Resolution
Dimensions & Mass: Metric Standard Flange
Application Fit: Standard continuous duty automation cells
VERIFIED Specification
6. Target Industrial Applications

Verified Deployment Scenarios & Operating Environments

Every application below reflects documented load capabilities, thermal equilibrium boundaries, and kinematics integration for Dual-Channel Safety Evaluation Relay with Force-Guided Contacts.

Explore All Industry Solutions
Scenario 01 Verified Deployment

Standalone robotic welding workstations

Environment: Automated production facilities and manufacturing cells

Operational Challenge:

Demanding precision positioning and repeatability requirements under high-duty continuous operation.

How Dual-Channel Safety Evaluation Relay with Force-Guided Contacts Solves It:

Provides calibrated Dual-Channel Safety Evaluation Relay with Force-Guided Contacts performance adhering strictly to ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots).

Required Supporting Subsystems:
  • Standard 24V AC/DC safety circuits
Considerations: Category 4 / PLe compliance
Ensure operating envelope stays within continuous S1 ratings under ambient temperatures ≤ 45°C.
Scenario 02 Verified Deployment

Single-station benchtop assembly presses

Environment: Automated production facilities and manufacturing cells

Operational Challenge:

Demanding precision positioning and repeatability requirements under high-duty continuous operation.

How Dual-Channel Safety Evaluation Relay with Force-Guided Contacts Solves It:

Provides calibrated Dual-Channel Safety Evaluation Relay with Force-Guided Contacts performance adhering strictly to ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots).

Required Supporting Subsystems:
  • Standard 24V AC/DC safety circuits
Considerations: Category 4 / PLe compliance
Ensure operating envelope stays within continuous S1 ratings under ambient temperatures ≤ 45°C.
Scenario 03 Verified Deployment

Safety gate interlock monitoring

Environment: Automated production facilities and manufacturing cells

Operational Challenge:

Demanding precision positioning and repeatability requirements under high-duty continuous operation.

How Dual-Channel Safety Evaluation Relay with Force-Guided Contacts Solves It:

Provides calibrated Dual-Channel Safety Evaluation Relay with Force-Guided Contacts performance adhering strictly to ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots).

Required Supporting Subsystems:
  • Standard 24V AC/DC safety circuits
Considerations: Category 4 / PLe compliance
Ensure operating envelope stays within continuous S1 ratings under ambient temperatures ≤ 45°C.
7. Engineering Benefits & Causality

Technical Feature → Engineering Effect → Customer Advantage

Every customer advantage below is linked directly to an underlying physical or electronic design feature. Operating boundaries and verification conditions are explicitly declared.

1. Technical Feature

Category 4 / PLe compliance

2. Engineering Effect

Provides deterministic mechanical and electrical response across operating ranges.

3. Customer Benefit

Prevents positioning drift and increases overall equipment effectiveness (OEE).

Verification & Operating Boundaries:Audited per ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots); continuous operating temperature ≤ 50°C.
1. Technical Feature

Manual monitored reset or automatic reset selection

2. Engineering Effect

Provides deterministic mechanical and electrical response across operating ranges.

3. Customer Benefit

Prevents positioning drift and increases overall equipment effectiveness (OEE).

Verification & Operating Boundaries:Audited per ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots); continuous operating temperature ≤ 50°C.
1. Technical Feature

Slim DIN-rail width (22.5 mm)

2. Engineering Effect

Provides deterministic mechanical and electrical response across operating ranges.

3. Customer Benefit

Prevents positioning drift and increases overall equipment effectiveness (OEE).

Verification & Operating Boundaries:Audited per ISO 13849-1 / ISO 13849-2 · IEC 62061 · ISO 10218-1/2 (Industrial Robots) · ISO/TS 15066 (Cobots); continuous operating temperature ≤ 50°C.
8. Integration & Compatibility

Mechanical, Electrical & Control Interfaces

Standardized interfaces for drop-in mechanical alignment, regulated power delivery, and deterministic fieldbus synchronization with host PLC and motion controllers.

Mechanical Interface

Mechanical Mounting & Interfaces

Standard 24V AC/DC safety circuits

Universal mounting in horizontal, vertical, or inverted orientations with precision dowel hole alignment.

Electrical & Power

Electrical & Power Specifications

48V DC Regulated Bus (24V–56V range)

Integrated field-oriented control or compatible with standard industrial AC/DC servo inverters.

Fieldbus Synchronization

Control & Fieldbus Synchronization

Cycle Time ≤ 1.0 ms (Jitter < 1 µs)

Supports cyclic synchronized position (CSP), velocity (CSV), and torque (CST) operating modes.

Supported Industrial Fieldbuses & Safety Protocols
EtherCAT (CoE / CiA 402)CANopen (DS402)PROFINET RT / IRTEtherNet/IP CIP SyncModbus RTU / TCPISO 13849-1 Safe Torque Off (STO)
9. Technical Documentation & CAD Models

Datasheets, 3D STEP Geometry & User Manuals

All engineering assets are revision-controlled and traceable to physical laboratory test benches. Request calibrated files directly from our engineering desk without broken links.

INTERACTIVE 3D CAD KINEMATICSIND-SAF-FORCE-GUIDED-SAFETY-RELAY // STEP AP242 / GLTF
IND-SAF-FORCE-GUIDED-SAFETY-RELAY
Full 3D Kinematic Envelope
DATUM ORIGIN (0,0,0)
Click & drag to rotate 3D assembly · Scroll to zoom
Calibrated Geometric Model:IND-SAF-FORCE-GUIDED-SAFETY-RELAY_ASSEMBLY.STEP
Conforms to ISO 10303-242 / DIN 3990. Includes full mating constraints and collision envelopes.
DatasheetPDF · 4.8 MB

Dual-Channel Safety Evaluation Relay with Force-Guided Contacts Engineering Datasheet & Sizing Curves

DS-IND-IND-SAF-FO-2026

Audited Lab Specification

CAD 3D STEPSTEP / AP214 · 32.6 MB

Dual-Channel Safety Evaluation Relay with Force-Guided Contacts 3D STEP Assembly Geometry Model

CAD-IND-IND-SAF-FO-STEP

Accurate C.G. Matrix

ManualPDF · 6.4 MB

Dual-Channel Safety Evaluation Relay with Force-Guided Contacts Integration & Commissioning Manual

MAN-IND-IND-SAF-FO-2026

Official Documentation

11. Frequently Asked Questions

Technical FAQs & Integration Guidelines

Direct answers to common engineering questions regarding sizing verification, mechanical tolerances, fieldbus integration, and documentation for Dual-Channel Safety Evaluation Relay with Force-Guided Contacts.

Selection requires calculating the root-mean-square (RMS) torque and reflected load inertia ratio under worst-case acceleration. Use the INDUS online sizing tools or submit your duty cycle to our application engineering team for verification against factory thermal curves.
12. Engineering Consultation & RFQ

Need Help Selecting the Right Product?

Connect directly with an INDUS motion systems engineer to verify sizing calculations, evaluate thermal duty cycles, request 3D STEP models, or configure custom flange interfaces.

Selected Product:Dual-Channel Safety Evaluation Relay with Force-Guided Contacts
Product Identifier:ind-saf-force-guided-safety-relay
Engineering Family:Safety Controllers & Interlocks
Standard Conformance:ISO 13849-1
Need immediate sizing advice?

• Official NDA protected technical evaluation

• 24 business hours standard proposal response

• Factory direct engineering support & CAD integration

Request Official Quotation & Application Verification

Prefilled with Dual-Channel Safety Evaluation Relay with Force-Guided Contacts specifications. Fill in your details below.